Return to search
Data Storage Products Filers V3140-BASE

PRODUCT SUMMARY
NetApp V3140-BASE Base Filer System - New
Price:

Brand: NetApp
Condition: New
Itemcode: V3140-BASE
Warranty: 3 Year Next Business Day
Description
Warranty
Payment
Shipping
Policies
Description:

This is a NEW NetApp V3140 Filer System Base with a Five Year Next Business Day Warranty.


This V3140 is a 6U rack-mountable system filer in which the system enclosure contains a single controller. The V3140 can cluster internally to double both the performance and fail safe redundancy. The V3140 is scalable up to 672TB with the addition of up to 48 additional disk shelves and 672 hard drives. Please see table below for detailed specifications.


NetApp® V-Series open storage controllers provide advanced storage efficiency, data protection, and data management, while maintaining your current storage investments. Manage disk arrays from EMC, IBM, HP, Hitachi, and other major vendors as if they were NetApp storage. Expand capacity by adding NetApp disk shelves.


Overview:



Specifications on the V3140:


V3140 Technical Highlights
Maximum RAID Group Sizes RAID-DP (high performance RAID 6)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 16 (14 data disks plus 2 parity disks)

RAID 4
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)
SAN Protocol Support Fibre Channel Protocol (FCP) for SCSI (4/2/1Gb); fabric-attached and direct-attached; IP SAN(iSCSI)
File Service Protocol Support NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS
Other Protocol Support HTTP 1.0, HTTP 1.1 virtual hosts
LUNs Up to 2,048 server host LUNs
FlexVol Volumes Up to 500 per controller
Volume/Aggregate Size 16TB
Snapshot Copies Up to 127,000
Number of Supported Hosts Up to 12 ports per controller configured as front-end (host) connectivity ports
Up to 12 directly connected servers (per controller and per active-active configuration)
Up to 256 SAN connected servers (per controller and per active-active configuration)
Supported Configurations Highly Available Controller Configurations
Active-active controller with controller failover, active-active controller with stretch (non switch) MetroCluster, active-active controller with fabric-attached MetroCluster

Highly Available Back-End (Disk) Configurations
Dual-path, multipath HA storage
Reliability Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports
Management Onboard serial console, diagnostic LED, full-duplex 10/100Base-T Ethernet remote LAN management port with RLM and onboard management interfaces, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts
Security Virus Protection
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role Based Access Control (RBAC)

Scalability V3140
Active/Active
Configuration
Single
Controller
Max. Raw Capacity 420TB 420TB
Max. Number of Disk Drives 420 420
Max. Drives per Back-End (Disk) FC Loop 84 84
ECC Memory 8GB 4GB
Nonvolatile Memory 1GB 512MB

I/O V3140
Active/Active
Configuration
Single
Controller
Onboard (fixed) Fibre Channel Ports (target or initiator) 8 ports 1, 2, or 4Gb (auto-sensing) 4 ports 1, 2, or 4Gb (auto-sensing)
Onboard (fixed) GbE Ports 4 2
Modular I/O Slots 8 4
RAID-6 is the recommended configuration for drives greater than 144 GB.
RLM module is an optional capability on the V3140 that is included at no charge with SupportEdge Premium contract.

I/O Card Support V3140
Active/Active
Configuration
Single
Controller
Dual FC Disk Adapters (max.) 8 4
Dual 4Gb FC Target Adapters (max.) 4 2
Quad 4Gb FC Disk/Tape Adapters (max.) 8 4
Quad 4Gb FC Target Adapter (max.) 6 3
Dual-port SCSI HBA 8 4
Optional Network Connectivity (max.)
Quad GbE TOE (copper) cards
Single 10GbE TOE (fiber) cards
Dual GbE (copper or fiber) cards
Dual iSCSI (copper or fiber) host adapter

8
8
8
8

4
4
4
4

Storage Specifications
Disk Shelves Supported (Fibre Channel, SATA) DS14, DS14mk2 FC, DS14mk2AT
Each w/14 low-profile slots for FC and SATA disk drives; DS4243, Dual-path,MPHA (MultiPath High Availability)
Disk Drive Support Disks Supported on New Configurations
FC-144GB, 300GB disks
SATA-250GB, 500GB disks

Disks Supported for Legacy (Controller Upgrade) Configurations
FC-36GB, 72GB, 144GB, 300GB disks
SATA-250GB, 320GB, 500GB disks
Disk Shelf Support Shelves Supported on New Configurations
Embedded Switched Hub (ESH)
Embedded Switched Hub2 (ESH2)
AT-FCX

Shelves Supported for Legacy (Controller Upgrade) Configurations
Embedded Switched Hub (ESH)
Embedded Switched Hub2 (ESH2)
AT-FCX
LRC
Disk Drive Storage Shelf Interface Fibre Channel-Arbitrated Loop (FC-AL)
Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies
AC Power/Max. Current SATA: 7200 RPM drives: 3.01/1.51/7.4A @ 100VAC/200VAC/-40VDC
FC: 10,000 RPM drives: 3.09/1.56/7.61A @ 100VAC/200VAC/-40VDC
FC: 15,000 RPM drives: 3.96/1.94/10.22 @ 100VAC/200VAC/-40VDC
Thermal Rating SATA 7200 RPM drives: 1017 BTU/hr
FC: 10,000 RPM drives: 1043 BTU//hr
FC: 15,000 RPM drives: 1394 BTU/hr
Operating Acoustic Noise 49 dBA sound pressure (LpA) @ normal operating conditions (at 22C and at sea level)
Dimensions (height/width/depth) 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight 77 lb (35 kg) fully loaded
V3140 has PCI-x I/O slots.
Protection Manager was previously known as Business Continuance Option
Operations Manager was previously known as Data Fabric Manager (DFM).

FC Switch Support- Tape/SAN
Vendor Model
Brocade Silkworm 2400/2800 (TapeSAN only)
Brocade Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000
McData ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
Qlogic 5600/5602
Cisco MDS 9120/9140/9216/9506/9509/9513/9124
FC = Fibre Channel; LVD = Low Voltage Differential

NetApp Systems Cabinet
20A and 30A single phase cabinets.

20A Cabinet - Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors

30A Cabinet - Includes 24 power cords with NEMA L6-30P or IEC 309 connectors
20A Cabinet: 1 FAS3100 chassis & 12 DS14-type shelves

30A Cabinet: 1 FAS3100 chassis & 12 DS-14 type shelves
AC Power 200 to 240VAC
Current Redundant power
20A Cabinet - Maximum 32A total
30A Cabinet - Maximum 24A total
Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances 48" (122 cm) front and rear
Shipping Height 90.6" (230 cm)
Weight (empty) 275 lb (125 kg)

FAS System Specifications Active/Active Configuration Single Controller Configuration
Weight 122 lb (68 kg) 95 lb (34 kg)
Height 10.24" (26 cm), fits into 6U space 10.24" (26 cm), fits into 6U space
Width 19" IEC rack-compliant (17.7", 44.9 cm)
Depth 24.3" (61.7 cm), 28" (71.1 cm) with cable management bracket
Operating Temperature, Altitude, and Relative Humidity 10 C to 40 C (50 F to 104 F); at 3,000 m (at 10,000' feet) elevation; 20% to 80% relative humidity, non-condensing (28 C wet bulb temperature)
Non-operating Temperature and Relative Humidity -40 C to 70 C (-40 F to 158 F); 5% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22 C and at sea level)
Min. Cabinet Clearances for Airflow 10" (25.4 cm) in front, 12" (30.5 cm) in rear
Min. Cabinet Clearances for Service 30" (76.2 cm ) in front, 30" (76.2 cm) in rear
Compliance RoHS-compliant
Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, BCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3

FAS3100 Series System Power Specifications
Model Input Voltage
Active/Active
Single Controller
Typical
Maximum
Typical
Maximum
One Side
Both Sides
One Side
Both Sides
FAS3140 100-120VAC Current, A 2.99 5.97 7.38 1.89 3.77 3.98
Power, W 297 594 736 187 373 396
Thermal, BTU/hr 1013 2026 2509 636 1272 1350
200-240VAC Current, A 1.49 2.98 3.6 0.97 1.93 1.97
Power, W 291 581 712 183 366 385
Thermal, BTU/hr 991 1981 2427 625 1249 1313
V3140 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07
Power, W 405 810 969 235 470 505
Thermal, BTU/hr 1381 2761 3305 801 1602 1722
200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52
Power, W 394 778 930 230 459 493
Thermal, BTU/hr 1343 2686 3170 782 1564 1680
FAS3170 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07
Power, W 405 810 969 235 470 505
Thermal, BTU/hr 1381 2761 3305 801 1602 1722
200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52
Power, W 394 778 930 230 459 493
Thermal, BTU/hr 1343 2686 3170 782 1564 1680


If you would like more information on the V3140: Please contact our sales department by sending an email to sales@berkcom.com or by calling us at (877) BERKCOM.

All related part numbers for this product:
V3140-BASE
Compatibility:
For questions about the compatibility of this product please contact us.