Return to search
Data Storage Products Filers V3170

PRODUCT SUMMARY
NetApp V3170 Base Filer System - New
Price:

Brand: NetApp
Condition: New
Itemcode: V3170
Warranty: 5 Year Next Business Day
Description
Warranty
Payment
Shipping
Policies
Description:

This is a New NetApp V3170 Filer System Base with a Five Year Next Business Day Warranty.

This V3170 is a 6U rack-mountable system filer in which the system enclosure contains a single controller. The V3170 can cluster internally to double both the performance and fail safe redundancy. The V3170 is scalable up to 800TB. Please see table below for detailed specifications.


V3100 Series Filers

NetApp V3100 series featuring Data ONTAP

With the V-Series, you can manage disk arrays from EMC, IBM, Hewlett-Packard, Hitachi Data Systems, and other major storage vendors as if they were NetApp® storage. You get advanced storage efficiency, data protection, and data management features while maintaining your current multiprotocol, multivendor storage investments.

  • You can dramatically increase your disk utilization and reclaim stranded capacity with thin provisioning and deduplication for primary storage, not just secondary storage.
  • Use the Snapshot™ software, the original and most functional point-in-time copy technology, to protect your data with no performance impact and minimal consumption of storage space. Replicate data across your global network at high speeds simply, efficiently, and flexibly with SnapMirror® for disaster recovery.
  • Accelerate application development and testing by using the FlexClone® technology to instantly replicate data volumes and data sets as transparent, virtual copies. NetApp clones can increase productivity and save storage space without compromising performance.

  • V3100 Series Key Points:

  • Scale to over 800TB of capacity on a single V3100 system.
  • Manage disk arrays from major vendors as if they were NetApp storage.
  • Increase disk utilization and reclaim stranded capacity.
  • Achieve application-level recovery in minutes, not hours.


    If you would like more information on the V3170:
    Please contact our sales department by sending an email to sales@berkcom.com or by calling us at (877) BERKCOM.


    Specifications on the V3160:


    V3170 Technical Highlights
    Maximum RAID Group Sizes RAID-DP (high performance RAID 6)
    FC: 28 (26 data disks plus 2 parity disks)
    SATA: 16 (14 data disks plus 2 parity disks)

    RAID 4
    FC: 14 (13 data disks plus 1 parity disk)
    SATA: 7 (6 data disks plus 1 parity disk)

    RAID 0 (striping over third-party Array LUNs)

    SyncMirror (high resiliency RAID !)
    Options:
      1. RAID-DP + RAID 1
      2. RAID 4 + RAID 1

    SAN Protocol Support Fibre Channel Protocol (FCP) for SCSI (4/2/1Gb); fabric-attached and direct-attached; IP SAN(iSCSI), Fibre Channel over Ethernet (FCoE)
    File Service Protocol Support NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS
    Other Protocol Support HTTP 1.0, HTTP 1.1 virtual hosts
    LUNs Up to 2,048 server host LUNs
    FlexVol Volumes Up to 500 per controller
    Volume/Aggregate Size 16TB
    Snapshot Copies Up to 127,000
    Number of Supported SAN Hosts Up to 12 ports per controller configured as front-end (host) connectivity ports
    Up to 12 directly connected servers (per controller and per active-active configuration)
    Up to 256 SAN connected servers (per controller and per active-active configuration)
    Supported Configurations Highly Available Controller Configurations
    Active-active controller with controller failover, active-active controller with stretch (non switch) MetroCluster, active-active controller with fabric-attached MetroCluster

    Highly Available Back-End (Disk) Configurations
    Dual-path, multipath HA storage
    Reliability Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports
    Management Onboard serial console, diagnostic LED, full-duplex 10/100Base-T Ethernet remote LAN management port with RLM and onboard management interfaces, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts
    Security Virus Protection
    Authentication: Kerberos (MIT/Active Directory)
    Authorization: LDAP, NIS
    Auditing: File access logging
    Encryption: IPSec, SSL, SSH, SMB signing
    Role Based Access Control (RBAC)

    Scalability V3170
    Active/Active
    Configuration
    Single
    Controller
    Maximum Number of Disk Drives(TB) 1680TB 1680TB
    Max. Number of Disk Drives 840 840
    Max. Drives per Back-End (Disk) FC Loop 84 84
    ECC Memory 32GB 16GB
    Nonvolatile Memory 4GB 2GB

    I/O V3170
    Active/Active
    Configuration
    Single
    Controller
    Onboard (fixed) Fibre Channel Ports (target or initiator) 8 ports 1, 2, or 4Gb (auto-sensing) 4 ports 1, 2, or 4Gb (auto-sensing)
    Onboard (fixed) GbE Ports 4 2
    Modular I/O Slots 8 4
    RAID-DP is the recommended configuration for drives greater than 144 GB.
    RLM module is an optional capability on the V3170 that is included at no charge with SupportEdge Premium contract.

    I/O Card Support V3170
    Active/Active
    Configuration
    Single
    Controller
    Dual FC Disk Adapters (max.) 8 4
    Dual 4Gb FC Target Adapters (max.) 4 2
    Quad 4Gb FC Disk/Tape Adapters (max.) 8 4
    Quad 4Gb FC Target Adapter (max.) 6 3
    Dual-port SCSI HBA 8 4
    Optional Network Connectivity (max.)
    Quad GbE TOE (copper) cards
    Single 10GbE TOE (fiber) cards
    Dual GbE (copper or fiber) cards
    Dual iSCSI (copper or fiber) host adapter

    8
    8
    8
    8

    4
    4
    4
    4
    Dual 10 GbE FCoE (copper of fiber) Target (SAN) Adapter (max)

    8

    4
    Performance Acceleration Module (max cards))

    8

    4
    512GB Flash Cache (max cards)
    4 2

    Storage Specifications
    Disk Shelves Supported (Fibre Channel, SATA, SAS) DS14, DS14mk2 FC, DS14mk2AT
    Each w/14 bays for 3.5" low-profile slots for FC and SATA disk drives
    DS4243 (24 - slots for SAS & SATA disk drives)
    Disk Drive Support Disks S8pported on New Configurations
    FC-144GB, 300GB
    SATA-250GB, 500GB, 1 TB, 2TB
    SAS-300GB, 450GB, 600GB

    Disks Supported for Legacy (Controller Upgrade) Configurations
    FC-36GB, 72GB, 144GB, 300GB
    SATA-250GB, 320GB, 500GB
    Disk Shelf Support Shelves Supported on New Configurations
    FC: DS14mk4 FC with Embedded Switched Hub 4 (ESH4)
    SATA: DS14mk2 AT with AT-FCX Electronics

    Supported via Upgrade Migrations from Installed Systems
    FC: DS14mk4 FC with ESH4 Electronics
    DS14mk2 FC with ESH4 or ESH2 Electronics
    SATA: DS14mk2 AT with AT-FCX Electronics
    Disk Drive Storage Shelf Interface Fibre Channel-Arbitrated Loop (FC-AL)
    Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies
    AC Power/Max. Current SATA: 7200 RPM drives: 3.01/1.51/7.4A @ 100VAC/200VAC/-40VDC
    FC: 10,000 RPM drives: 3.09/1.56/7.61A @ 100VAC/200VAC/-40VDC
    FC: 15,000 RPM drives: 3.96/1.94/10.22 @ 100VAC/200VAC/-40VDC
    Thermal Rating SATA 7200 RPM drives: 1017 BTU/hr
    FC: 10,000 RPM drives: 1043 BTU//hr
    FC: 15,000 RPM drives: 1394 BTU/hr
    Operating Acoustic Noise 49 dBA sound pressure (LpA) @ normal operating conditions (at 22C and at sea level)
    Dimensions (height/width/depth) 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
    Weight 77 lb (35 kg) fully loaded
    V3170 has PCI-x I/O slots.
    Protection Manager was previously known as Business Continuance Option
    Operations Manager was previously known as Data Fabric Manager (DFM).

    Storage Arrays Supported by V3100
    Storage Interface/Data Rate) PCI-Based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4Gb/sec
    Storage Arrays IBM
    Enterprise Storage Server (ESS), DS 4000 storage

    HDS
    USP Platform, AMS, Lightning Series, Thunder Series, SANRISE Series (Japan Only)

    HP
    StorageWorks XP Arrays, StorageWorks Enterprise Virtual Arrays

    EMC
    Symmetrix, Clariion

    Fujitsu
    ETERNUS Platform

    3PAR
    InServ Family

    SUN
    Storagetek

    FC Switch Support- Tape/SAN
    Vendor Model
    Brocade Silkworm 2400/2800 (TapeSAN only)
    Brocade Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000
    McData ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
    Qlogic 5600/5602
    Cisco MDS 9120/9140/9216/9506/9509/9513/9124
    FC = Fibre Channel; LVD = Low Voltage Differential

    NetApp Systems Cabinet
    20A and 30A single phase cabinets.

    20A Cabinet - Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors

    30A Cabinet - Includes 24 power cords with NEMA L6-30P or IEC 309 connectors
    20A Cabinet: 1 V3100 chassis & 12 DS14-type shelves

    30A Cabinet: 1 V3100 chassis & 12 DS-14 type shelves
    AC Power 200 to 240VAC
    Current Redundant power
    20A Cabinet - Maximum 32A total
    30A Cabinet - Maximum 24A total
    Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
    Min. Clearances 48" (122 cm) front and rear
    Shipping Height 90.6" (230 cm)
    Weight (empty) 275 lb (125 kg)

    V3100 System Specifications Active/Active Configuration Single Controller Configuration
    Weight 122 lb (68 kg) 95 lb (34 kg)
    Height 10.24" (26 cm), fits into 6U space 10.24" (26 cm), fits into 6U space
    Width 19" IEC rack-compliant (17.7", 44.9 cm)
    Depth 24.3" (61.7 cm), 28" (71.1 cm) with cable management bracket
    Operating Temperature, Altitude, and Relative Humidity 10 C to 40 C (50 F to 104 F); at 3,000 m (at 10,000' feet) elevation; 20% to 80% relative humidity, non-condensing (28 C wet bulb temperature)
    Non-operating Temperature and Relative Humidity -40 C to 70 C (-40 F to 158 F); 5% to 95% relative humidity, non-condensing, in original container
    Operating Acoustic Noise ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22 C and at sea level)
    Min. Cabinet Clearances for Airflow 10" (25.4 cm) in front, 12" (30.5 cm) in rear
    Min. Cabinet Clearances for Service 30" (76.2 cm ) in front, 30" (76.2 cm) in rear
    Compliance RoHS-compliant
    Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R

    Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, BCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3

    V3100 Series System Power Specifications
    Model Input Voltage
    Active/Active
    Single Controller
    Typical
    Maximum
    Typical
    Maximum
    One Side
    Both Sides
    One Side
    Both Sides
    V3140 100-120VAC Current, A 2.99 5.97 7.38 1.89 3.77 3.98
    Power, W 297 594 736 187 373 396
    Thermal, BTU/hr 1013 2026 2509 636 1272 1350
    200-240VAC Current, A 1.49 2.98 3.6 0.97 1.93 1.97
    Power, W 291 581 712 183 366 385
    Thermal, BTU/hr 991 1981 2427 625 1249 1313
    V3160 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07
    Power, W 405 810 969 235 470 505
    Thermal, BTU/hr 1381 2761 3305 801 1602 1722
    200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52
    Power, W 394 778 930 230 459 493
    Thermal, BTU/hr 1343 2686 3170 782 1564 1680
    V3170 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07
    Power, W 405 810 969 235 470 505
    Thermal, BTU/hr 1381 2761 3305 801 1602 1722
    200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52
    Power, W 394 778 930 230 459 493
    Thermal, BTU/hr 1343 2686 3170 782 1564 1680
All related part numbers for this product:
V3170
Compatibility:
For questions about the compatibility of this product please contact us.