Brand: | NetApp | |
Condition: | New | |
Itemcode: | V3170 | |
Warranty: | 5 Year Next Business Day |
This is a New NetApp V3170 Filer System Base with a Five Year Next Business Day Warranty.
This V3170 is a 6U rack-mountable system filer in which the system enclosure contains a single controller. The V3170 can cluster internally to double both the performance and fail safe redundancy. The V3170 is scalable up to 800TB. Please see table below for detailed specifications.
V3100 Series Filers
NetApp V3100 series featuring Data ONTAP
With the V-Series, you can manage disk arrays from EMC, IBM, Hewlett-Packard, Hitachi Data Systems, and other major storage vendors as if they were NetApp® storage. You get advanced storage efficiency, data protection, and data management features while maintaining your current multiprotocol, multivendor storage investments.
- You can dramatically increase your disk utilization and reclaim stranded capacity with thin provisioning and deduplication for primary storage, not just secondary storage.
- Use the Snapshot™ software, the original and most functional point-in-time copy technology, to protect your data with no performance impact and minimal consumption of storage space. Replicate data across your global network at high speeds simply, efficiently, and flexibly with SnapMirror® for disaster recovery.
- Accelerate application development and testing by using the FlexClone® technology to instantly replicate data volumes and data sets as transparent, virtual copies. NetApp clones can increase productivity and save storage space without compromising performance.
- Scale to over 800TB of capacity on a single V3100 system.
- Manage disk arrays from major vendors as if they were NetApp storage.
- Increase disk utilization and reclaim stranded capacity.
- Achieve application-level recovery in minutes, not hours.
If you would like more information on the V3170: Please contact our sales department by sending an email to sales@berkcom.com or by calling us at (877) BERKCOM.
Specifications on the V3160:
V3170 Technical Highlights Maximum RAID Group Sizes RAID-DP (high performance RAID 6)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 16 (14 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)
RAID 0 (striping over third-party Array LUNs)
SyncMirror (high resiliency RAID !)
Options:- 1. RAID-DP + RAID 1
2. RAID 4 + RAID 1
SAN Protocol Support Fibre Channel Protocol (FCP) for SCSI (4/2/1Gb); fabric-attached and direct-attached; IP SAN(iSCSI), Fibre Channel over Ethernet (FCoE) File Service Protocol Support NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS Other Protocol Support HTTP 1.0, HTTP 1.1 virtual hosts LUNs Up to 2,048 server host LUNs FlexVol Volumes Up to 500 per controller Volume/Aggregate Size 16TB Snapshot Copies Up to 127,000 Number of Supported SAN Hosts Up to 12 ports per controller configured as front-end (host) connectivity ports
Up to 12 directly connected servers (per controller and per active-active configuration)
Up to 256 SAN connected servers (per controller and per active-active configuration)Supported Configurations Highly Available Controller Configurations
Active-active controller with controller failover, active-active controller with stretch (non switch) MetroCluster, active-active controller with fabric-attached MetroCluster
Highly Available Back-End (Disk) Configurations
Dual-path, multipath HA storageReliability Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports Management Onboard serial console, diagnostic LED, full-duplex 10/100Base-T Ethernet remote LAN management port with RLM and onboard management interfaces, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts Security Virus Protection
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role Based Access Control (RBAC)
Scalability V3170 Active/Active
ConfigurationSingle
ControllerMaximum Number of Disk Drives(TB) 1680TB 1680TB Max. Number of Disk Drives 840 840 Max. Drives per Back-End (Disk) FC Loop 84 84 ECC Memory 32GB 16GB Nonvolatile Memory 4GB 2GB
I/O V3170 Active/Active
ConfigurationSingle
ControllerOnboard (fixed) Fibre Channel Ports (target or initiator) 8 ports 1, 2, or 4Gb (auto-sensing) 4 ports 1, 2, or 4Gb (auto-sensing) Onboard (fixed) GbE Ports 4 2 Modular I/O Slots 8 4 RAID-DP is the recommended configuration for drives greater than 144 GB.
RLM module is an optional capability on the V3170 that is included at no charge with SupportEdge Premium contract.
I/O Card Support V3170 Active/Active
ConfigurationSingle
ControllerDual FC Disk Adapters (max.) 8 4 Dual 4Gb FC Target Adapters (max.) 4 2 Quad 4Gb FC Disk/Tape Adapters (max.) 8 4 Quad 4Gb FC Target Adapter (max.) 6 3 Dual-port SCSI HBA 8 4 Optional Network Connectivity (max.)
Quad GbE TOE (copper) cards
Single 10GbE TOE (fiber) cards
Dual GbE (copper or fiber) cards
Dual iSCSI (copper or fiber) host adapter
8
8
8
8
4
4
4
4Dual 10 GbE FCoE (copper of fiber) Target (SAN) Adapter (max)
8
4Performance Acceleration Module (max cards))
8
4512GB Flash Cache (max cards)
4 2
Storage Specifications Disk Shelves Supported (Fibre Channel, SATA, SAS) DS14, DS14mk2 FC, DS14mk2AT
Each w/14 bays for 3.5" low-profile slots for FC and SATA disk drives
DS4243 (24 - slots for SAS & SATA disk drives)Disk Drive Support Disks S8pported on New Configurations
FC-144GB, 300GB
SATA-250GB, 500GB, 1 TB, 2TB
SAS-300GB, 450GB, 600GB
Disks Supported for Legacy (Controller Upgrade) Configurations
FC-36GB, 72GB, 144GB, 300GB
SATA-250GB, 320GB, 500GB
Disk Shelf Support Shelves Supported on New Configurations
FC: DS14mk4 FC with Embedded Switched Hub 4 (ESH4)
SATA: DS14mk2 AT with AT-FCX Electronics
Supported via Upgrade Migrations from Installed Systems
FC: DS14mk4 FC with ESH4 Electronics
DS14mk2 FC with ESH4 or ESH2 Electronics
SATA: DS14mk2 AT with AT-FCX ElectronicsDisk Drive Storage Shelf Interface Fibre Channel-Arbitrated Loop (FC-AL) Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies AC Power/Max. Current SATA: 7200 RPM drives: 3.01/1.51/7.4A @ 100VAC/200VAC/-40VDC
FC: 10,000 RPM drives: 3.09/1.56/7.61A @ 100VAC/200VAC/-40VDC
FC: 15,000 RPM drives: 3.96/1.94/10.22 @ 100VAC/200VAC/-40VDCThermal Rating SATA 7200 RPM drives: 1017 BTU/hr
FC: 10,000 RPM drives: 1043 BTU//hr
FC: 15,000 RPM drives: 1394 BTU/hrOperating Acoustic Noise 49 dBA sound pressure (LpA) @ normal operating conditions (at 22C and at sea level) Dimensions (height/width/depth) 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) Weight 77 lb (35 kg) fully loaded V3170 has PCI-x I/O slots.
Protection Manager was previously known as Business Continuance Option
Operations Manager was previously known as Data Fabric Manager (DFM).
Storage Arrays Supported by V3100 Storage Interface/Data Rate) PCI-Based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4Gb/sec Storage Arrays IBM
Enterprise Storage Server (ESS), DS 4000 storage
HDS
USP Platform, AMS, Lightning Series, Thunder Series, SANRISE Series (Japan Only)
HP
StorageWorks XP Arrays, StorageWorks Enterprise Virtual Arrays
EMC
Symmetrix, Clariion
Fujitsu
ETERNUS Platform
3PAR
InServ Family
SUN
Storagetek
FC Switch Support- Tape/SAN Vendor Model Brocade Silkworm 2400/2800 (TapeSAN only) Brocade Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000 McData ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700 Qlogic 5600/5602 Cisco MDS 9120/9140/9216/9506/9509/9513/9124 FC = Fibre Channel; LVD = Low Voltage Differential
NetApp Systems Cabinet 20A and 30A single phase cabinets.
20A Cabinet - Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors
30A Cabinet - Includes 24 power cords with NEMA L6-30P or IEC 309 connectors20A Cabinet: 1 V3100 chassis & 12 DS14-type shelves
30A Cabinet: 1 V3100 chassis & 12 DS-14 type shelvesAC Power 200 to 240VAC Current Redundant power
20A Cabinet - Maximum 32A total
30A Cabinet - Maximum 24A totalDimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) Min. Clearances 48" (122 cm) front and rear Shipping Height 90.6" (230 cm) Weight (empty) 275 lb (125 kg)
V3100 System Specifications Active/Active Configuration Single Controller Configuration Weight 122 lb (68 kg) 95 lb (34 kg) Height 10.24" (26 cm), fits into 6U space 10.24" (26 cm), fits into 6U space Width 19" IEC rack-compliant (17.7", 44.9 cm) Depth 24.3" (61.7 cm), 28" (71.1 cm) with cable management bracket Operating Temperature, Altitude, and Relative Humidity 10 C to 40 C (50 F to 104 F); at 3,000 m (at 10,000' feet) elevation; 20% to 80% relative humidity, non-condensing (28 C wet bulb temperature) Non-operating Temperature and Relative Humidity -40 C to 70 C (-40 F to 158 F); 5% to 95% relative humidity, non-condensing, in original container Operating Acoustic Noise ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22 C and at sea level) Min. Cabinet Clearances for Airflow 10" (25.4 cm) in front, 12" (30.5 cm) in rear Min. Cabinet Clearances for Service 30" (76.2 cm ) in front, 30" (76.2 cm) in rear Compliance RoHS-compliant Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, BCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3
V3100 Series System Power Specifications Model Input Voltage Active/ActiveSingle ControllerTypicalMaximum TypicalMaximum One SideBoth SidesOne SideBoth SidesV3140 100-120VAC Current, A 2.99 5.97 7.38 1.89 3.77 3.98 Power, W 297 594 736 187 373 396 Thermal, BTU/hr 1013 2026 2509 636 1272 1350 200-240VAC Current, A 1.49 2.98 3.6 0.97 1.93 1.97 Power, W 291 581 712 183 366 385 Thermal, BTU/hr 991 1981 2427 625 1249 1313 V3160 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07 Power, W 405 810 969 235 470 505 Thermal, BTU/hr 1381 2761 3305 801 1602 1722 200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52 Power, W 394 778 930 230 459 493 Thermal, BTU/hr 1343 2686 3170 782 1564 1680 V3170 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07 Power, W 405 810 969 235 470 505 Thermal, BTU/hr 1381 2761 3305 801 1602 1722 200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52 Power, W 394 778 930 230 459 493 Thermal, BTU/hr 1343 2686 3170 782 1564 1680
V3100 Series Key Points:
V3170